== The Sample code source bin you can download from ==
== The Sample code source bin you can download from ==
Line 11: Line 12:
== How to use NEX-001 test program? ==
== How to use NEX-001 test program? ==
-
[[Image:NEX-001test.jpg]]
+
1.Use make to compile the test file. After completion, you can enter the BIN folder and execute the test program.
-
1.Select the model or use the scanner to read the hardware information, if there is none, you can skip
+
[[Image:NEX-001menu.jpg]]
-
2.Select the function to test
+
2.Select the model or use the scanner to read the hardware information, if there is none, you can skip
 +
 
 +
3.Select the function to test
'''Note: NEX-001 cannot use functions 4, 5, and 6'''
'''Note: NEX-001 cannot use functions 4, 5, and 6'''
Line 39: Line 42:
[[Image:NEX-001can_cable.jpg]]
[[Image:NEX-001can_cable.jpg]]
 +
 +
2.Check the CCA1 signal and connect it correctly
 +
 +
[[Image:NEX-001can_CCA1.jpg]]
 +
 +
 +
3.In the program, select ALL TEST or Test Felxcan to see that the CAN option is correct when it is completed
 +
 +
[[Image:NEX-001can_report.jpg]]

Current revision

Contents

The Sample code source bin you can download from

<Google Drive>

Binary file: NEX-001Y_v1.0_bin.zip

<FTP>

Binary file: NEX-001Y_v1.0_bin.zip

How to use NEX-001 test program?

1.Use make to compile the test file. After completion, you can enter the BIN folder and execute the test program.

Image:NEX-001menu.jpg

2.Select the model or use the scanner to read the hardware information, if there is none, you can skip

3.Select the function to test

Note: NEX-001 cannot use functions 4, 5, and 6

How to test NEX-001 COM?

1. You need a device to receive the signal. We use RS485 to RS232 as a test tool

Image:NEX-001com_cable.jpg

2. Check the CCA1 signal and connect it correctly

Image:NEX-001com_CCA1.jpg

3.In the program, select ALL TEST to see that the COM option is correct when it is completed

Image:NEX-001com_comport.jpg


How to test NEX-001 CAN?

1.A parallel line is needed to connect can0 and can1 with DuPont line

Image:NEX-001can_cable.jpg

2.Check the CCA1 signal and connect it correctly

Image:NEX-001can_CCA1.jpg


3.In the program, select ALL TEST or Test Felxcan to see that the CAN option is correct when it is completed

Image:NEX-001can_report.jpg