DPC Module:Brightness setting utility under DOS

From LEXWiKi

(Difference between revisions)
Jump to: navigation, search
(New page: Category:AllowPages == DPC_Dos Utility Download == This utility is used to set brightness rapidly, and use with batch file at mass production.<br /> <br /> Download Binary file: [ft...)
Current revision (13:47, 25 February 2022) (edit) (undo)
(DPC_Dos Utility Download)
 
(13 intermediate revisions not shown.)
Line 5: Line 5:
This utility is used to set brightness rapidly, and use with batch file at mass production.<br />
This utility is used to set brightness rapidly, and use with batch file at mass production.<br />
<br />
<br />
-
Download Binary file: [ftp://ftp.lex.com.tw/Engineer/SoftSupport/AP_Module/DPC_release/Dos_base/DPC_DOS_v1.0.rar DPC_DOS_v1.0 Binary]<br />
+
Binary file:
 +
 
 +
<Google Drive> [https://drive.google.com/file/d/1qDvLZ8Me8DYVjdxNL8qo6lRZ_ZWNZikP/view?usp=sharing DPC_DOS_v1.0_Bin]
 +
 
 +
<FTP> [ftp://ftp.lex.com.tw/Engineer/SoftSupport/AP_Module/DPC_release/Dos_base/DPC_DOS_v1.0.rar DPC_DOS_v1.0_Bin]
<br />
<br />
== How to Use ==
== How to Use ==
-
command:<br />
+
<font Size="3">command:</font><br />
-
/s Num1 Num2 -Setting panel frequency and duty cycle.<br />
+
;/s Num1 Num2 :-Setting panel frequency and duty cycle.<br />
*Num1 is "Panel Frequency", and Num2 is "Duty Cycle". The unit of panel frequency is "Hz", and the range of duty cycle is "0~100".<br />
*Num1 is "Panel Frequency", and Num2 is "Duty Cycle". The unit of panel frequency is "Hz", and the range of duty cycle is "0~100".<br />
-
/VX900 -If CPU is VX900, you have to add this parameter.<br />
+
;/VX900 :-If CPU is VX900, you have to add this parameter.<br />
-
/h -Goto DPC_Dos v1.0 Manual.<br />
+
;/h :-Goto DPC_Dos v1.0 Manual.<br />
For example: If a panel's frequency is 20kHz and you want to set 50 as its duty cycle. you can use this command as follow.<br />
For example: If a panel's frequency is 20kHz and you want to set 50 as its duty cycle. you can use this command as follow.<br />

Current revision


DPC_Dos Utility Download

This utility is used to set brightness rapidly, and use with batch file at mass production.

Binary file:

<Google Drive> DPC_DOS_v1.0_Bin

<FTP> DPC_DOS_v1.0_Bin

How to Use

command:

/s Num1 Num2  
-Setting panel frequency and duty cycle.
  • Num1 is "Panel Frequency", and Num2 is "Duty Cycle". The unit of panel frequency is "Hz", and the range of duty cycle is "0~100".
/VX900  
-If CPU is VX900, you have to add this parameter.
/h  
-Goto DPC_Dos v1.0 Manual.

For example: If a panel's frequency is 20kHz and you want to set 50 as its duty cycle. you can use this command as follow.

DPCDOS /s 20000 50
  • Be careful that some panels' duty cycle are decrease, the default duty cycle is 100. And others' default duty cycle are increase, its duty cycle is 0.