Battery Monitor Utility under Windows

From LEXWiKi

(Difference between revisions)
Jump to: navigation, search
Line 94: Line 94:
=== Detail information about individual battery ===
=== Detail information about individual battery ===
[[Image:bmu_DetailPage.png]]<br /><br />
[[Image:bmu_DetailPage.png]]<br /><br />
-
'''After click the Button, "Battery Long Time Monitor", from the Battery Info, user will enter the Long Time Monitor setup dialog box to configure the parameters for the battery event log.'''<br />
+
'''Press the "Battery 1" or "Battery 2" Button. Show battery information and detail about warn status.'''<br />
-
*A.Temperature Threshold: user can designate the preferred threshold value. The overheating event will be recorded in batterylog.txt once the battery temperature has exceeded the set threshold value.<br />
+
*2-1.Detail about warn status. If features is not active, led is 'grey'. If warn status is normal, led is 'green'. Otherwise is 'red'.<br />
-
*B.“New temperature threshold value” will appear in RED C after clicked the "Apply".<br />
+
*2-2.Status: Over temperature. If temperature of battery is under 'Over temperature threshold', led is 'green'. Otherwise is 'red'.<br />
-
*D.The Over temperature warning will appear as shown below when the action of "Run User Temperature Threshold" has been activated and exceeded the temperature.<br />
+
*2-3.Status: Under temperature. If temperature of battery is higher 'Under temperature threshold', led is 'green'. Otherwise is 'red'.<br />
-
[[Image:otemp.png]]<br />
+
*2-4.Status: Low battery capacity. If capacity of battery is higher 'Low battery capacity threshold', led is 'green'. Otherwise is 'red'.<br />
-
*E.The Battery Long Time Monitor will set to refresh & record the monitor values after the set interval value (minimum value is 30 sec).<br />
+
*2-5.Status: External power removed. If external power removed from device, led is 'red'. Otherwise is 'green'.<br />
-
*F.Checked the button, it will detect battery life percent when starting long time monitor, and if the percent is lower than shutdown percent(Red F) which you set, it will shutdown automatically.<br />
+
 
-
*H.Activate the Battery Long Time Monitor (RED H) after complete the parameters and the event log will be saved as batterylog.txt under BMU_bin_w folder<br />
+
Batterylog file as below picture as show<br />
Batterylog file as below picture as show<br />

Revision as of 16:23, 28 July 2020

If you want to read the introduction of Chinese version, please click the below link:
Battery Monitor Utility for bq2084 简体中文版

Contents

Introduction

Battery Monitor Utility is battery monitor software for retrieving & auto-saving the battery information.
It could also protect the battery from overheating by the preset threshold value.

The Sample code source and Spec File you can download from

Source file(old): PW016_src_w.zip

Source file: BMU4bq2084_src_2.6.1.zip

Binary file: BMU_Setup_V2.6.1_x64.zip

Binary file: BMU_Setup_V2.6.1_x86.zip

(※新版本如需移除請進入控制台進行移除)

How to use Battery Monitor Utility

Install BMU_Setup for your windows environment. And start Battery Monitor Utility.

When you click the close button of the utility, it will hide into tray icon like below picture.
If you want to know some simple information of battery, you can move the cursor to tray icon, it will show the battery status.
Image:bmu_trayiconMsg.png

If you want to see the detail of battery, you can double-click the tray icon, battery monitor utility will appear.
You can also click right button on tray icon and select "More Battery Info" to evoke battery monitor utility.
Image:tray_menu.png

Error Code Table

ErrorCode = 2

System can't find necessary files.

ErrorCode = 3

System can't find corresponding path.

ErrorCode = 4

Utility may loss necessary files.

Solution: Check installation directory and files in directory are not moved/ removed.
For example, if using 32 bit version, check "WinIO.sys" and "WinIO.dll" exists or not. If using 64 bit version, check "LexIO64.sys" and "LexIO64.dll" exists or not.

ErrorCode = 5

Access denied.

Solution: If operation system is Windows 7, make sure to run utility as Administrator.

ErrorCode = 1275

The driver version doesn't match operating system.

Solution: If operating system is 32 bit version, checking the utility is also 32 bit version and vice versa.

edit table

Battery Monitor Utility main page

Image:bmu_MainUI.png

When start utility, it will show simple information about all batteries on the main page.
If you want to watch detail message about individual battery, you can press the buttons on the left panel.

About page items detail is below.

  • 1-1. Press button to show simple information about all batteries.
  • 1-2. Press button to show detail information about battery one.
  • 1-3. Press button to show detail information about battery two.
  • 1-4. Press button to show configuration page.
  • 1-5. External power voltage. Support PW407 only.
  • 1-6. Count of all battery device on the motherboard.
  • 1-7. Battery Monitor Utility software version.
  • 1-8. PW407 firmware version.
  • 1-9. Battery one simple information.
  • 1-10. Warning led of Battery one. If battery status normal, led is green. If warning happened, led is red.

Image:bmu_WarnLed.png

  • 1-11.Battery Status for Charge or Discharge.
  • 1-12.Battery Status for Remaining capacity percent.
  • 1-13.Battery remaining life time.
  • 1-14.Battery Temperature.
  • 1-15.Battery Current.
  • 1-16.Battery Voltage.
  • 1-17.Press button to shut dowe battery.
  • 1-18.Battery two simple information.

Detail information about individual battery

Image:bmu_DetailPage.png

Press the "Battery 1" or "Battery 2" Button. Show battery information and detail about warn status.

  • 2-1.Detail about warn status. If features is not active, led is 'grey'. If warn status is normal, led is 'green'. Otherwise is 'red'.
  • 2-2.Status: Over temperature. If temperature of battery is under 'Over temperature threshold', led is 'green'. Otherwise is 'red'.
  • 2-3.Status: Under temperature. If temperature of battery is higher 'Under temperature threshold', led is 'green'. Otherwise is 'red'.
  • 2-4.Status: Low battery capacity. If capacity of battery is higher 'Low battery capacity threshold', led is 'green'. Otherwise is 'red'.
  • 2-5.Status: External power removed. If external power removed from device, led is 'red'. Otherwise is 'green'.


Batterylog file as below picture as show
Image:batterylog.png
Image:battery_refresh.jpg
(Battery Long Time Monitor has been activated.)

  • I.Capacity Threshold: user can appoint the preferred threshold value. If battery is low-capacity, the utility will pop-up a warning message.
  • J."New capacity threshold value" will appear in RED K after clicked the "Apply".
  • L,N."New capacity threshold value" will appear in RED K after clicked the "Apply".
  • O.The low capacity warning message will pop-up when the action of "Run User Capacity Threshold" has been activated and in the status of low-capacity.

Application Config

Image:battery_config.png
You can set "Auto startup", "Hide when startup" and "Auto start long time monitoring" in this dialog.

  • Auto startup: Operating battery monitor utility automatically when the device booting.
  • Hide when startup: The utility will be minimized when it starupped.
  • Auto start long time monitoring: The utility will operate long time monitoring automatically when it starupped.

SDK Reference Code Introduction

int GotBatteryCurrent(void)
float GotBatteryTemperature(void)
int GotBatteryVoltage(void)
int GotBatteryLifePercent(void)
WORD GotBatteryLifeTime(void)
bool CPW016_UtilityDlg::Gotalarm(void)

Personal tools