請先看『使用說明』
MB:CV766C
From LEXWiKi
(Difference between revisions)
(→How can I use Serial port COM5 and COM6 in Linux?) |
(→Driver Support) |
||
Line 166: | Line 166: | ||
| | | | ||
*[ftp://ftp.lex.com.tw/Engineer/SoftSupport/Driver/SBC_Board/CV700/WinCE_60/viabsp_v3.43_for_ce60.zip VGA & Audio & LAN] | *[ftp://ftp.lex.com.tw/Engineer/SoftSupport/Driver/SBC_Board/CV700/WinCE_60/viabsp_v3.43_for_ce60.zip VGA & Audio & LAN] | ||
- | *[ | + | *[http://tprd.info/lexwiki/index.php/MB:CV766C#Sloving_WinCE_6.0_image_booting_problem_with_SATA_device. SATA] |
| | | | ||
Line 174: | Line 174: | ||
[{{SERVER}}/lexwiki/index.php?title=Special:TableEdit&id=0ff043503afcc820715377de1ca000b6.0.N478cd4d5c87b9&page=0&pagename={{FULLPAGENAMEE}} edit table] | [{{SERVER}}/lexwiki/index.php?title=Special:TableEdit&id=0ff043503afcc820715377de1ca000b6.0.N478cd4d5c87b9&page=0&pagename={{FULLPAGENAMEE}} edit table] | ||
<!--box uid=0ff043503afcc820715377de1ca000b6.0.N478cd4d5c87b9--> | <!--box uid=0ff043503afcc820715377de1ca000b6.0.N478cd4d5c87b9--> | ||
+ | |||
== FAQ of CV766C == | == FAQ of CV766C == | ||
=== Enable RS232 (COM1~COM4) support in WinCE 6.0 by setting platform.reg file. === | === Enable RS232 (COM1~COM4) support in WinCE 6.0 by setting platform.reg file. === |
Revision as of 11:28, 12 January 2010
Contents |
Driver Support
O.S. | VGA | Audio | IDE | Video-in | TV-OUT | LAN | Download | Patch |
---|---|---|---|---|---|---|---|---|
Windows XP Embedded |
Yes |
Yes |
Yes |
- |
No |
Yes | ||
Windows CE 5.0 |
Yes |
Yes |
Yes |
- |
No |
Yes | ||
Ubuntu 7.10 |
Yes |
Yes |
Yes |
- |
No |
Yes |
| |
Debian 4.0 |
Yes |
Yes |
Yes |
- |
No |
Yes |
| |
Suse10.3 |
Yes |
Yes |
Yes |
- |
No |
Yes |
| |
Fedora Core 7 |
Yes |
Yes |
Yes |
- |
No |
Yes | ||
Fedora Core8 |
Yes |
Yes |
Yes |
- |
No |
Yes | ||
Windows CE 6.0 |
Yes |
Yes |
Yes |
- |
No |
Yes |
FAQ of CV766C
Enable RS232 (COM1~COM4) support in WinCE 6.0 by setting platform.reg file.
Ans: |
IF BSP_SERIAL3 "Ranges"="0-0x5F,0x65-0x277,0x284-0x2E7,0x2F0-0x2F7,0x300-0x38F,0x392-0x3DF,0x3E2-0x3E7,0x3F0-0xFFFF" "Ranges"="0-0x5F,0x65-0x277,0x284-0x2E7,0x2F0-0x2F7,0x300-0x38F,0x392-0x3DF,0x3E2-0x3E7,0x3F0-0x3F7,0x400-0xFFFF" ENDIF BSP_SERIAL3 IF BSP_SERIAL2 "SerialDbg1"="Drivers\\BuiltIn\\Serial2" "SerialDbg4"="Drivers\\BuiltIn\\Serial2" ENDIF BSP_SERIAL2 . . . IF BSP_SERIAL3 "SerialDbg3"="Drivers\\BuiltIn\\Serial3" "SerialDbg5"="Drivers\\BuiltIn\\Serial3" ENDIF BSP_SERIAL3 . . . IF BSP_NOSERIAL ! [HKEY_LOCAL_MACHINE\Drivers\BuiltIn\Serial] "SysIntr"=dword:13 "SysIntr"=dword:14 "IoBase"=dword:02F8 "IoBase"=dword:03F8 . . . IF BSP_SERIAL2 [HKEY_LOCAL_MACHINE\Drivers\BuiltIn\Serial2] "SysIntr"=dword:14 "SysIntr"=dword:13 "IoBase"=dword:03F8 "IoBase"=dword:02F8 . . . ENDIF BSP_SERIAL2 IF BSP_SERIAL3 [HKEY_LOCAL_MACHINE\Drivers\BuiltIn\Serial3] "SysIntr"=dword:15 "IoBase"=dword:02E8 "IoBase"=dword:03E8 . . . ENDIF BSP_SERIAL3 [HKEY_LOCAL_MACHINE\Drivers\BuiltIn\Serial4] "SysIntr"=dword:1A "IoBase"=dword:02E8 "IoLen"=dword:8 "DeviceArrayIndex"=dword:3 "Prefix"="COM" "IClass"="{CC5195AC-BA49-48a0-BE17-DF6D1B0173DD}" "Dll"="Com16550.Dll" "Order"=dword:0 "Flags"=dword:10 ; User MOde: DEVFLAGS_LOAD_AS_USERPROC [HKEY_LOCAL_MACHINE\Drivers\BuiltIn\Serial4\Unimodem] "Tsp"="Unimodem.dll" "DeviceType"=dword:0 "DevConfig"=hex: 10,00, 00,00, 05,00,00,00, 10,01,00,00, 00,4B,00,00, 00,00, 08, 00, 00, 00,00,00,00 #if ! (defined IMGPPC || defined IMGTPC) "FriendlyName"=LOC_FRIENDLYNAME_SERIAL4 "FriendlyName"="Serial Cable on COM4:" #else (defined IMGPPC || defined IMGTPC) {BEGIN MULTILANG} ; @BEGINASSOC LOCALE %LANGID% [HKEY_LOCAL_MACHINE\Drivers\BuiltIn\Serial4\Unimodem] "FriendlyName"=LOC_%LANGID%_FRIENDLYNAME_SERIAL4 ;"FriendlyName"="Serial Cable on COM4:" ; @ENDASSOC {END MULTILANG} #endif ! (defined IMGPPC || defined IMGTPC) ENDIF BSP_NOSERIAL ! . . . |
---|---|
Patch File: |
N/A |
Defect: |
N/A |
Asker: |
Eric Wu 09:27, 26 August 2008 (CST) |
Provider: |
Eric Wu 09:27, 26 August 2008 (CST) |
Sloving WinCE 6.0 image booting problem with SATA device.
Ans: |
Location is : Third Party -> Devices Drivers -> VIA PATA/SATA Storage Block Driver
Location is : Device Drivers -> Storage Devices -> ATAPI PCI Support |
---|---|
Patch File: |
N/A |
Defect: |
N/A |
Asker: |
Eric Wu 11:04, 26 August 2008 (CST) |
Provider: |
Eric Wu 11:04, 26 August 2008 (CST) |
How can I use Serial port COM5 and COM6 in Linux?
Ans: |
#vi /boot/grub/menu.lst Add "8250.nr_uarts=6" in the kernel line as below picture:
#reboot And then you can use 6 COM ports. |
---|---|
Patch File: |
N/A |
Defect: |
N/A |
Asker: |
Patty 17:12, 6 March 2009 (CST) |
Provider: |
Patty 17:12, 6 March 2009 (CST) |