CPC Utility under Linux

From LEXWiKi

(Difference between revisions)
Jump to: navigation, search
(CPC Utility Setting Window)
Line 17: Line 17:
<br />
<br />
=== CPC Utility Setting Window ===
=== CPC Utility Setting Window ===
-
[[Image:CPC_Setting1.png]]<br />
+
[[Image:CPCsertting-1.png]]<br />
<br />
<br />
;1. I<sup>2</sup>C Address: Default is "B6".<br />
;1. I<sup>2</sup>C Address: Default is "B6".<br />
Line 23: Line 23:
<br />
<br />
<br />
<br />
-
[[Image:CPC_Setting2.png]]<br />
+
[[Image:CPCsertting-2.png]]<br />
;3. Delay Main Power On: Set delay time which CPC turn on computer .<br />
;3. Delay Main Power On: Set delay time which CPC turn on computer .<br />
;4. OS Delay Off: Set delay time which CPC turn off computer.<br />
;4. OS Delay Off: Set delay time which CPC turn off computer.<br />
Line 33: Line 33:
<br />
<br />
<br />
<br />
-
[[Image:CPC_Setting3.png]]<br />
+
[[Image:CPCsertting-3.png]]<br />
;9. Reset Button: Press the button to enable CPC basic setting section and set again.<br />
;9. Reset Button: Press the button to enable CPC basic setting section and set again.<br />
;10. Recent Battery Value Check Frequency: The value is check frequency when starting to monitor.<br />
;10. Recent Battery Value Check Frequency: The value is check frequency when starting to monitor.<br />

Revision as of 12:31, 6 June 2012

CPC Utility Download

Binary file:
Source file:

How to Use The Utility

Image:CPC_Utility_Main.jpg

1. Setting Button
Open "Setting Window".
2. Battery Setting Button
Open "Battery Setting Window".
* Kindly notice that you have to set I2C Address in setting window before open battery setting window.
3. Recently Voltage Value
Utility will detect the recent voltage value and show in the edit box when start to monitor.
4. Period Voltage Value
Utility will detect and show the period voltage value when start "under low voltage detect". If "under low voltage detect" doesn't execute, period voltage value will be hidden.
5. Operation Mode
6. Battery Type
Show the battery type you set.
* If disable "under low voltage detect", battery type will be hidden.
7. Start Button
Press this button will start to monitor and show battery information on utility main window.
* Kindly notice that you have to set I2C Address in setting window before starting to monitor.


CPC Utility Setting Window

Image:CPCsertting-1.png

1. I2C Address
Default is "B6".
2. Submit Button
Press this button when finish selecting I2C address, then CPC Basic Setting section and CPC Monitor Setting section will be enable to set(like the picture below).



Image:CPCsertting-2.png

3. Delay Main Power On
Set delay time which CPC turn on computer .
4. OS Delay Off
Set delay time which CPC turn off computer.
5. Main Power Delay
Set delay time of power supply after computer is turned off.
6. Load Default Button
Press thie button will load default value of CPC basic setting section.
* In CPC basic setting section, the initial value are read from registers.
7. Read Register Button
Press this button will read the value from register.
8. Set Button
Press this button to set when finish selecting what you want to set in CPC basic setting section. After press the button, CPC basic setting section will be disable.



Image:CPCsertting-3.png

9. Reset Button
Press the button to enable CPC basic setting section and set again.
10. Recent Battery Value Check Frequency
The value is check frequency when starting to monitor.
* The range of check frequency is between 5 to 60 seconds.
11. Start on Boot
If enable this function, the utility will execute when the OS boot.
12. Confirm Button
If finish to set CPC Monitor Setting section, press this button and the information will be set.
13. Cancel Button



Personal tools